BACK TO MINDSET

SCREEN IMAGES
FROM MINDSET SOFTWARE


MINDSET SCSI
SOLUTIONS

in Adobe Acrobat
(PDF) Format

MINDSET PRESS RESUME
in Adobe Acrobat
(PDF) Format




MINDSET MS-1000
Mindset was created in 1993 by Aquathought for extremely demanding field research. After years of continuous development and refinement, Mindset emerges into the market as a robust and comprehensive tool for EEG study.


FEATURES

Composite and Band-separated
Realtime Topographic Neuromaps

color models, bands of interest, resolution, Windows movie creation, epochs and more under user control.

Strip Chart Waveform Display
channels of interest, sweep rate, amplitude scale and screen configuration are configurable on-the-fly.

Wavelab Offline Analysis
allows for wave data editing, de-artifacting, whole session analysis, standardized metric reporting, neurometric profile comparative analysis and more.

Fast Fourier Transform
user selectable area of interest, configurable window, overlap, scale, inverse FFT and automatic peak detection.

Compressed Spectral Array
realtime visualization of spectral data with on-the- fly configuration of channels of interest, time scale, amplitude scale and screen layout.

Spectral Histogram
fully user configurable realtime display with on-the- fly control of channels of interest, epoch length, amplitude scale and screen layout.

User Dialog-box Controls
make operation and setup easy by providing on-the- fly point and click control over all aspects of the data recording, visualization, and storage.

Cross-Coherence Analysis
compare coherence of any two channels in realtime.

Electrode Signal Verification
verify proper electrode preparation and recording at a glance.

MIDI Device Control
provides realtime sonification of user specified aspects of EEG.



SPECIFICATIONS

Channels
16 differential input channels (32 input jacks)

Resolution
16 bit analog to digital converter 1024 samples-per-second-per-channel (programmable from 64)

Filtration
2 fourth-order Sallen-Key active filters, 48bd roll-off per octave 1.8hz - 36 hz frequency pass band

Common Mode Rejection
120bd maximum, 87db typical in pass band

Input Range
0 - 100 microvolts* (* 0-400 microvolt range using optional gain variance module)

Electrodes
standard electrode inputs (compatible with Electro-Cap and e-Net)

Montage Reference Configuration
user selectable through Expansion Connector Linked-Ear Referential module supplied

Interface to Computer
SCSI (Standard Centronics type connectors)

Opto-Isolation
2500 volts RMS

Total Harmonic Distortion
-87db .01% servo linearity

Calibration
factory calibrated*, automatic and user calibration via software (*optional calibration certificate available)

Power
110/220vlts, 50/60hz input 15 watts consumption

Operational Temperature
32ºf - 90ºf, do not operate in direct sunlight

Dimensions and Weight
13" deep, 11.31" wide, 3.88" high main unit - 7 pounds, external power supply - 2 pounds

Warranty
Mindset is warranted to be free from defects which affect proper operation, for a period of one year.

System Requirements
Pentium Class or 486 PC running Windows 95 or NT. SCSI interface, 8 megs of RAM, 20 megs of available hard drive space. (For optimum realtime neuromapping, 133Mhz Pentium or better- is recommended).

Optional Accessories
Montage Breakout Module, Tandem Unit Module, Gain Variance Module, Calibration Certificate, Notebook Grounding Harness.



Mindset is a registered trademark of Aquathought Labs. Specifications are subject to change without notice.